1. HOME
  2. HOME_eng
  3. Product
  4. Electric wire
  5. Equipment wire (code)
  6. Single-core vinyl cord

Single-core vinyl cord
VSF/HVSF/USH-VSF/125-VSF

Single-core vinyl cord


【feature】
●It is used for small electrical appliances of 300V or less.
●It has passed the vertical flame resistance test of the Electrical Appliance and Material Safety Law.
(Equivalent to UL standard VW-1.)
●We manufacture each size up to a nominal cross-sectional area of 5.5e.

【Specifications by application】
●Non-migration (SB)

電子機器用ビニル電線

VSF

【Rated】
Voltage:300V
temperature:60℃

HVSF

【Rated】
Voltage:300V
temperature:75℃

USH-VSF

【Rated】
Voltage:300V
temperature:105℃

125-VSF

【Rated】
Voltage:300V
temperature:125℃

conductor vinyl insulator
nominal cross-sectional area(㎟) composition( /mm) outer diameter(mm) thickness(mm) outer diameter(mm) 
0.5 20/0.18 0.9 0.8 2.5
0.75 30/0.18 1.1 2.7
1.25 50/0.18 1.5 3.1
2.0 37/0.26 1.8 3.4

 

 

 

〇In addition to the above, we will design and manufacture various special specifications upon request.〇